The YSI 2700 SELECT Biochemistry Analyzer provides vital information about your processes. It provides rapid, accurate analysis of key nutrients and byproducts, including:

 

  • -  Glucose
  • -  Lactate
  • -  Glutamine
  • -  Glutamate
  • -  Ethanol
  • -  Lactose
  • -  Sucrose
  • -  Galactose
  • -  Hydrogen peroxide
  • -  Methanol
  • -  Starch
  • -  Choline
  • -  Xylose

 

The YSI 2700 can be configured in single or dual analyte mode. Combine many of the analytes above. Popular combinations include glucose/lactate, glutamine/glutamate, sucrose/glucose and xylose/glucose. Sample analysis can be carried out in two ways, benchtop or on-line.

 

 

 

 

Product Specifications
 
 

 

YSI 2700 SELECT Biochemistry Analyzer

Product Specifications
Aspirated sample volume: User selects 5 to 65 microliters
Analysis time: 60 seconds
Precision: <2% CV, n=10
Linearity: ±5%*, calibration value to range maximum
Calibration: User selects frequency
Size: 35.6 x 25.4 x 35.6 cm, 11.4 kg
(14 x 10 x 14 inches, 25 lbs)
Working environment: 15 to 35°C ambient temperature,
10 to 90% relative humidity (noncondensing)
Power: 110-120 VAC or 220-240 VAC
50-60 Hz
50 Watts nominal
Battery backup: Rechargeable Ni-Cad batteries to back up RAM.
Regulatory Compliance: CE, CSA

YSI 2710 Turntable

Sample containers: 10 to 16 mm dia, 20 to 100 mm height
Sample wheel: 19.1 dia x 1.9 cm
(7.5 dia x 0.75 in)
Size: 23.5 x 20.3 x 12.7 cm, 2.5 kg
(9.25 x 8 x 5 in, 5.5 lbs)

YSI 2730 Monitor & Control Accessory

Sample inlet tubing: Silicone, 0.08" OD x 0.02" ID; Volume: 5.1 microliters per inch
Inlet channel pump tubing: PharMedTM 0.13" OD x 0.035" ID
Valve tubing: 0.03" ID
Wasteline tubing: Silicone, 0.16" OD x 0.10" ID
Nominal flow rate (inlet line): 100 to 2500 microliters per minute (±8% @ ±6 PSI)
Sample interval: 2 minutes to 1,000 hours
Analog/Control
Full Scale Voltage: Selectable: +10.00 VDC or +5.00 VDC
Full Scale Concentration: User selectable via software as 1, 2, 3 or
4 x Calibrant Concentration.
Resolution: 1:4096 or 0.02% FS, 2.44 mV on +10.00 VFS, 1.22 mV on +5.00 VFS
Maximum Offset: ±4 LSB
Linearity: ±1 LSB
Minimum analog output
Load Impedance:
2K Ohms
Logic output drive: 0 and 5 VDC nominal at 4 mA
Logic Input levels: < 0.8 VDC = logic 0,
> 3.5 VDC = logic 1
* Xylose ±15%

 

 

 

Option & Accessories

 

YSI 2700 SELECT Biochemistry Analyzer

Options & Accessories
Item Part Number
Single Channel Biochemistry Analyzer* 2700S
Dual Channel Biochemistry Analyzer* 2700D
Turntable 2710
Aseptic Monitoring & Control Accessory 2730
>IQ/OQ Documentation Package 2799
Printer Paper 5-pack 2751
Membrane Installation Solution 2392
Membrane Check Solution 2363
Preventive Maintenance Kit (2700) 2788
Preventive Maintenance Kit (2730) 2731
Data Logging Software 2340

*Specify 115 or 230 volt

Related Reagents

Chemistry Membrane System Buffer Calibration Standard Linearity Check Solution
Choline 2771 2357 2772 2773
Ethanol 2786 2787 2790 (kit) 2790 (kit)
Galactose 2702 2705 * *
Glucose 2365 2357 2776 2777
Hydrogen peroxide 2701 2357 * *
L-Glutamate 2754 2357 2755 2756
L-Glutamine 2735 2357 2736 2737
L-Lactate 2329 2357 2776 2777
Lactose 2702 2705 2783 2784
Methanol 2725 1579 2726 (kit) 2726 (kit)
Sucrose 2703 2357 2780 2778
Xylose 2761 2357 2767 2768

*User must prepare standards

IQ/OQ Documentation for your c-GMP Needs

YSI Life Sciences provides documentation that helps you with installation and operational qualifications if you are incorporating the YSI 2700 into manufacturing processes that require FDA-regulated products. Both hard copy and digital versions are available to incorporate into your documentation. If you need more than documents ask YSI about on-site services for IQ/OQ implementation. 

 

 

Application Notes


YSI has collaborated with scientists in industry and academia to provide protocols for the YSI 2700 SELECT in many different applications. If you would like to talk with a YSI representative about your specific application, please call or e-mail us. Below are descriptions of a few of the applications tested by YSI chemists:

Adobe® Reader® is required to view PDF (Portable Document Format) files.

 

 

Adobe

Adobe, Reader, and the Reader logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.

 

No. 301   Dextrose in Molasses (26k)

No. 302   Sucrose in Molasses (26k)

No. 303   Simultaneous Dextrose & Sucrose in Molasses (34k)

No. 304   Dextrose in Potatoes (33k)

No. 305   Simultaneous Dextrose & Sucrose in Potatoes (361k)

No. 306   Dextrose in Corn Syrup & Other Syrup Products (27k)

No. 307   Simultaneous Dextrose & Sucrose in Sweetened Condensed Milk (35k)

No. 308   Simultaneous Dextrose & Sucrose in Baked Goods (35k)

No. 309   Simultaneous Dextrose & Sucrose in Cereal Products (35k)

No. 310    Simultaneous Dextrose & Sucrose in Corn & Peas (35k)

No. 311    L-Lactate in Lunch Meats (25k)

No. 312    Dextrose in Frozen Green Beans (26k)

No. 313    Ethanol in Beer (26k)

No. 314    Dextrose in Canned Green Beans (26k)

No. 315    Simultaneous Dextrose & Sucrose Utilizing External Hydrolysis (38k)

No. 316    Simultaneous Dextrose & Sucrose in Ice Cream Bars (36k)

No. 317    Determination of Hydrogen Peroxide (26k)

No. 318    L-Glutamate Determination (26k)

No. 319    Determination of % Cook in Extruded Cereal Products Using Physical Solubilization (36k)

No. 320    Lactose Measurement in Cheese (26k)

No. 322    % Cook in Extruded Cereal Products Using Chemical Solubilization  (39k)

No. 323    Simultaneous Dextrose & Sucrose in Peanut Butter (35k)

No. 324    Choline Determination (25k)

No. 325    Simultaneous Measurement of Glutamine & Glutamate (35k)

No. 326    Rapid Measurement of Residual Ethanol in Corn Stillage (Beer) during Distillation (63k)

No. 327 Rapid Measurement of Glucose during Fermentation in Bioethanol Production (46k)

No. 328 Rapid Measurement of Xylose & Glucose Monitoring Corn Stover Fermentation in Bioethanol Production (172k)

No. 329 Simultaneous Measurement of L-Lactate and Ethanol in Tomato-based Products (66k)

Systems Application Notes

No. 202    Effluent Monitoring (58k)

No. 203    Aseptic Monitoring & Control (53k)

Contact YSI Life Sciences Technical Support for assistance with your sample application.

 

Catalog & References

 

http://www.ysilifesciences.com/uploads/LargePDFs/YSILS2005catalogp6-9NS.pdf